Safety distances to the sides of the
hob
Ideally the hob should be installed with
plenty of space on either side. There
may be a wall at the rear and a tall unit
or wall at one side. On the other side,
however, no unit or divider should
stand higher than the built-in appliance
(see illustrations).
Due to the high temperatures radiated
by the appliance, it is essential that a
minimum distance of 50 mm is
maintained between the worktop
cut-out and the back wall.
The following minimum distance a
between the worktop cut-out and a wall
or tall unit to the right or left of it must
be maintained:
40 mm for CS 1212 / CS 1212-1
CS 1221 / CS 1221-1
CS 1222
CS 1223
CS 1234 / CS 1234-1
50 mm for CS 1112
CS 1122
CS 1134
CS 1326
CS 1327
CS 1411
100 mm for CS 1012 / CS 1012-1
150 mm for CS 1421
CS 1312
CS 1322
200 mm for CS 1034 / CS 1034-1
250 mm for CS 1011
CS 1021.
Recommended
Not recommended
Not allowed